Search results for "Ion cyclotron resonance"

showing 10 items of 96 documents

A quartz amplifier for high-sensitivity Fourier-transform ion-cyclotron-resonance measurements with trapped ions

2019

Single-ion sensitivity is obtained in precision Penning-trap experiments devoted to light (anti)particles or ions with low mass-to-charge ratios, by adding an inductance coil to an amplifier connected to the trap, both operated at 4 K. However, single-ion sensitivity has not been reached on heavy singly or doubly charged ions. In this publication, we present a new system to reach this point, based on the use of a quartz crystal as an inductance, together with a newly developed broad-band (BB) amplifier. We detect the reduced-cyclotron frequency of 40Ca+ ions stored in a 7-tesla open-ring Penning trap. By comparing the detected electric signal obtained with the BB amplifier and the fluoresce…

010302 applied physicsMaterials scienceEquivalent series resistanceAmplifierPenning trap01 natural sciences7. Clean energySignalFourier transform ion cyclotron resonance010305 fluids & plasmasIonCrystal0103 physical sciencesAtomic physicsInstrumentationSensitivity (electronics)Review of Scientific Instruments
researchProduct

Kinetic instabilities in pulsed operation mode of a 14 GHz electron cyclotron resonance ion source

2016

The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz Aelectron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10- 100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime. peerReviewed

010302 applied physicsMaterials scienceta114Ion beamCyclotron resonancePlasma01 natural sciencesplasma electronsIon sourceElectron cyclotron resonanceFourier transform ion cyclotron resonance010305 fluids & plasmasMagnetic fieldpulsed operation modePhysics::Plasma Physics0103 physical scienceselectron cyclotron resonance ion sourceskinetic instabilitiesAtomic physicsInstrumentationIon cyclotron resonanceReview of Scientific Instruments
researchProduct

Cyclotron instability in the afterglow mode of minimum-B ECRIS.

2016

It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. I…

010302 applied physicsPhysicsta114ta213Astrophysics::High Energy Astrophysical Phenomenaplasma instabilityCyclotronBremsstrahlungPlasma01 natural sciencesInstabilityIon sourceElectron cyclotron resonance010305 fluids & plasmaslaw.inventionTwo-stream instabilityPhysics::Plasma Physicslaw0103 physical scienceselectron cyclotron resonance ion sourcesAtomic physicsInstrumentationIon cyclotron resonanceThe Review of scientific instruments
researchProduct

Equipping metallo-supramolecular macrocycles with functional groups: Assemblies of pyridine-substituted urea ligands

2012

A series of di-(m-pyridyl)-urea ligands were prepared and characterized with respect to their conformations by NOESY experiments and crystallography. Methyl substitution in different positions of the pyridine rings provides control over the position of the pyridine N atoms relative to the urea carbonyl group. The ligands were used to self-assemble metallo-supramolecular M(2)L(2) and M(3)L(3) macrocycles which are generated in a finely balanced equilibrium in DMSO and DMF according to DOSY NMR experiments and ESI FTICR mass spectrometry. Again, crystallography was used to characterize the assemblies. Methyl substitution in positions next to the pyridine nitrogen prevents coordination, while …

010405 organic chemistryHydrogen bondChemistryStereochemistrySupramolecular chemistryurea ligands; metallo-supramolecular macrocycles; X-ray structure; hydrogen-bonding010402 general chemistryMass spectrometry01 natural sciencesFourier transform ion cyclotron resonance0104 chemical sciencesInorganic ChemistrySubstituted ureaCrystallographychemistry.chemical_compoundPyridineUreaTwo-dimensional nuclear magnetic resonance spectroscopyta116Dalton Transactions
researchProduct

Characterization of NOM

2015

Worldwide reports over the last few decades have shown that the amount of natural organic matter (NOM) in surface water is continuously increasing, which has an adverse effect on drinking water purification. For many practical and hygienic reasons, the presence of NOM in drinking water is undesirable. Various technologies have been proposed for NOM removal with varying degrees of success. The properties and amount of NOM, however, can significantly affect the process efficiency. To improve and optimize these processes, it is essential to characterize and quantify NOM at various points during purification and treatment. It is also important to be able to understand and predict the reactivity…

AdsorptionChemistryMultidimensional NMR TechniquesEnvironmental chemistryPortable water purificationWater treatmentMass spectrometryPyrolysisSurface waterFourier transform ion cyclotron resonance
researchProduct

Characterization of oligomeric compounds in secondary organic aerosol using liquid chromatography coupled to electrospray ionization Fourier transfor…

2009

The components of secondary organic aerosols (SOAs) generated from the gas-phase ozonolysis of two C(10)H(16)-terpenes (alpha-pinene; sabinene) and a cyclic C(6)H(10) alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed-phase high-performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well-known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental …

AerosolsSpectrometry Mass Electrospray IonizationChromatographyChemistryElectrospray ionizationOrganic ChemistryAnalytical chemistryExtractive electrospray ionizationMass spectrometryTandem mass spectrometryFourier transform ion cyclotron resonanceIon sourceAnalytical ChemistryTandem Mass SpectrometryCyclohexenesSpectroscopy Fourier Transform InfraredMonoterpenesDirect electron ionization liquid chromatography–mass spectrometry interfaceChromatography High Pressure LiquidSpectroscopyBicyclic MonoterpenesAmbient ionizationRapid Communications in Mass Spectrometry
researchProduct

Ammonium ion mediated resorcarene capsules: ESI-FTICRMS study on gas-phase structure and ammonium ion affinity of tetraethyl resorcarene and its per-…

2003

AbstractThe ammonium ion binding affinities of tetraethyl resorcarene (1) and its per-methylated derivative (2) were studied by electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Ten different ammonium ions were tested as guests for the resorcarenes. A strong tendency for complex formation was observed with all ammonium ions of size and charge distribution suitable for noncovalent interactions with the cavities of the resorcarene hosts 1 and 2. Although differences in ammonium ion affinities were observed between 1 and 2 due to the dissimilar conformations, the overall tendency was that increase in the degree of substitution and the length of ca…

Ammonium bromideChemistryStereochemistryElectrospray ionizationIon cyclotron resonance spectrometryMass spectrometryFourier transform ion cyclotron resonanceInclusion compoundchemistry.chemical_compoundStructural BiologyPolymer chemistryAmmoniumAmmonium ion bindingSpectroscopyJournal of the American Society for Mass Spectrometry
researchProduct

Capillary electrokinetic fractionation mass spectrometry (CEkF/MS): Technology setup and application to metabolite fractionation from complex samples…

2014

Capillary electrokinetic fractionation (CEkF) is investigated as a new, simple, and robust approach for semipreparative and analytical sample analysis based on pKa -dependant pH-driven electrophoretic mobility. CEkF was optimized with contactless conductivity detection and conducted with 10 kV reverse voltage for 10 min, then coupled on/at-line to ESI/MS. We propose a semi-empirical model with 14 representative compounds based on the correlation between sample/medium pH regulating the partial charge, the electrokinetic loading of the capillary and intensity (I) of analytes. According to the model, an empirical function (I = f (pH)) could be derived to calculate the acid dissociation constan…

AnalyteChromatographySulfur CompoundsChemistryCapillary actionClinical BiochemistryAnalytical chemistryElectrophoresis CapillaryWineFractionationHydrogen-Ion ConcentrationMass spectrometryBiochemistryMass SpectrometryAcid dissociation constantAnalytical ChemistryElectrophoresisElectrokinetic phenomenaModels ChemicalSpectroscopy Fourier Transform InfraredIon cyclotron resonanceELECTROPHORESIS
researchProduct

Rapid determination of pharmaceuticals in wastewater by direct infusion HRMS using target and suspect screening analysis

2021

Abstract A wide-scope screening of active pharmaceutical ingredients (APIs) and their transformation products (TPs) in wastewater can yield valuable insights and pinpoint emerging contaminants that have not been previously reported. Such information is relevant to investigate their occurrence and fate in various environmental compartments. In this study, we explored the applicability of direct infusion high resolution mass spectrometry (DI-HRMS) for comprehensive and rapid detection of APIs and their TPs in wastewater samples. The method was developed using a Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) system and incorporated both wide-scope suspect screening and…

AnalyteEnvironmental EngineeringChromatography010504 meteorology & atmospheric sciencesWastewater010501 environmental sciencesQuechers01 natural sciencesPollutionRapid detectionFourier transform ion cyclotron resonanceScreening analysisPharmaceutical PreparationsWastewaterNorth AmericaEnvironmental ChemistryEnvironmental scienceSewage treatmentWaste Management and DisposalEffluentWater Pollutants ChemicalChromatography Liquid0105 earth and related environmental sciencesScience of The Total Environment
researchProduct

Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…

2019

Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…

AnalyteEnvironmental EngineeringMaterials scienceFood SafetyHalogenationHealth Toxicology and Mutagenesis0208 environmental biotechnologyAtmospheric-pressure chemical ionization02 engineering and technology010501 environmental sciences01 natural sciencesFourier transform ion cyclotron resonanceGas Chromatography-Mass SpectrometryMass SpectrometryCalibrationHalogenated Diphenyl EthersEnvironmental ChemistryHumans0105 earth and related environmental sciencesFlame RetardantsDetection limitChromatographyFourier AnalysisPublic Health Environmental and Occupational HealthGeneral MedicineGeneral ChemistryRepeatabilityCyclotronsPollution020801 environmental engineeringFoodFood productsGas chromatographyFood AnalysisChemosphere
researchProduct